Pedion24 Project


Summary

In February 2006, Mobile Radiocommunications Laboratory started the operation of the second electromagnetic radiation monitoring network in Greece, named “Pedion24” network. The development of this network was motivated by the lack of previous systematic measurement and recording of electromagnetic field strength levels over the country and aimed at providing valid, up-to-date information to citizens about the results of these measurements, namely, the exposure level to non-ionizing electromagnetic radiation.

Figure 1: Website of Pedion24 Project

Figure 2: System architecture.

The system at its present state (January 2019) comprises 245 remote monitoring stations spread all over Greece and four control units located in four University laboratories (National Technical University of Athens, Aristotle University of Thessaloniki, University of Aegean and University of Piraeus). The Mobile Radiocommunications Laboratory controls stations located in the Center part Greece, the Peloponnese, Crete, the Ionian Islands and Epirus, while the other three Universities controls the rest of the regions.

The stations are located at schools, universities, public authorities’ buildings and private flats. There are multiple criteria for the selection of the measurement sites. High population concentration is among the most important ones. The special features of each location, such as the presence of buildings of particular interest for the local community (e.g. schools and hospitals) and the existence of antennas in the close vicinity of the sites are also taken into account. It should be explicitly noted that the aim of this monitoring network is to provide the public with accurate information about the electromagnetic radiation at sensitive areas all over Greece rather than to measure the radiation emitted from specific antennas. As a result, the technical characteristics (emitted power, main lobes, etc) of the nearby antennas are not a priori known, as we do not focus on distinctive antennas.

Figure 3: Ad-hoc measurement setup. Figure 4: Measurement results: electric field strength on a weekly basis.

Figure 5: Measurement results: comparison of the measured electric field with the corresponding limits. Figure 6: Contribution of each sub-band to the total electric field.

Program Pedion24 Impact for ICCS / NTUA

The project Pedion24 is a development project and from 2006 up to date has funded many research activities of the Mobile Radiocommunications Laboratory of the NTUA, while from the project resources, the Laboratory equipment has been upgraded and expanded. Also, a requirement of the project is the certified electromagnetic radiation measurements according to the standard ISO17025:2005, as a result, the Mobile Radiocommunications Laboratory has been accredited with the above standard by the National Accreditation System (ESYD). Also, from the beginning of the project (2006) it offers four (4) jobs with contract. The engineers are accredited and able to perform electromagnetic radiation measurements while supporting the proper functioning and maintenance of the monitoring network.